產(chǎn)品說(shuō)明:
|
型號(hào)性能 |
S-400-9
|
S-400-12
|
S-400-13.5
|
S-400-24
|
S-400-48
|
直流輸出電壓
|
9V
|
12V
|
13.5V
|
24V
|
48V
|
輸出電壓容差
|
±1%
|
±1%
|
±1%
|
±1%
|
±1%
|
額定輸出電流
|
43A
|
33A
|
29A
|
17A
|
8.3A
|
輸出電流范圍
|
0-43A
|
0-33A
|
0-29A
|
0-17A
|
0-8.3A
|
紋波及噪音
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
150mVp-p
|
進(jìn)線穩(wěn)定度
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
負(fù)載穩(wěn)定度(注5)
|
±1%
|
±0.5%
|
±0.5%
|
±0.5%
|
±0.5%
|
直流輸出功率
|
387W
|
396W
|
400W
|
400W
|
400W
|
效率
|
78%
|
83%
|
85%
|
85%
|
86%
|
直流電壓可調(diào)范圍
|
±10%
|
±10%
|
±10%
|
±10%
|
±10%
|
輸入電壓范圍
|
170~264VAC
|
交流輸入電流
|
5.6A/115V 2.8A/230V
|
功率因素
|
0.95/100~240VAC
|
沖擊電流
|
40A/230V(冷態(tài)時(shí))
|
漏電流
|
<3.5mA/240VAC
|
過(guò)載保護(hù)
|
105%~135% 類型:FOLDBACK 切斷輸出 復(fù)位:自動(dòng)恢復(fù)
|
過(guò)電壓保護(hù)
|
9.4~10.9V
|
13.8~16.2V
|
15.5~18.2V
|
18~21V
|
57.6~67.2V
|
風(fēng)扇控制,O.T.P.
|
RTH1 or RTH2>=50℃ FAN ON,<=45℃ FAN OFF,>=70℃ 切斷輸出
|
溫度系數(shù)
|
±0.03%℃(0~50℃)
|
啟動(dòng)、上升、保持時(shí)間
|
1.5s,50ms,20ms
|
抗震性
|
10~500Hz,2G 10秒/1周期,共60分鐘,各軸
|
耐壓
|
輸入輸出間:3KVAC,輸入與外殼:1.5KVAC 輸出與外殼:0.5KVAC
|
隔離電阻
|
輸入輸出間,輸入與外殼,輸出與外殼:500VDC/100M Ohms
|
工作溫度、濕度
|
-10℃~+50℃,20%~90%RH
|
存儲(chǔ)溫度、溫度
|
-20℃~+85℃,10%~95%%RH
|
外形尺寸
|
241*124*65mm
|
重量
|
1.2Kgs
|
安全標(biāo)準(zhǔn)
|
UL1950,TUV EN60950
|
EMC標(biāo)準(zhǔn)
|
IEC1000-42,3,4,5,6,8,11 IEC100-3-2
|
注:1、以上參數(shù)測(cè)試條件為:230VAC輸入,額定負(fù)載,25℃ 70% RH.濕度。
2、容差:包括設(shè)定容差,線路穩(wěn)定度,負(fù)載穩(wěn)定度(注5)。
3、紋波測(cè)試:20MHz 用A12 "雙絞線,中斷用0.1uF&47uF電容器短路。
4、進(jìn)線電壓穩(wěn)定度測(cè)試:滿負(fù)載時(shí)進(jìn)線最低電壓到最高電壓。
5、負(fù)載穩(wěn)定度測(cè)試:負(fù)載從0%到100%,其他輸出為60%額定負(fù)載。
6、各輸出可達(dá)最大電流,但總負(fù)載不可超過(guò)最大輸出功率。
7、C2,3,11必須拆除。
|
|
|