型號
|
S-250-5 | S-250-7.5 | S-250-12 | S-250-13.5 | S-250-15 | S-250-24 | S-250-27 | S-250-48 | |||
輸出 |
直流輸出電壓 |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
48V |
||
輸出電壓容差 |
±2% |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
|||
額定輸出電流 |
40A |
30A |
20A |
18.5A |
16.6A |
10A |
9.3A |
5.2A |
|||
輸出電流范圍 |
0-40A |
0-30A |
0-20A |
0-18.5A |
0-16.6A |
0-10A |
0-9.3A |
0-5.2A |
|||
輸出功率 |
200W |
225W |
240W |
250W |
249W |
240W |
251W |
250W |
|||
紋波及噪音 |
120mVp-p |
120mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
240mVp-p |
|||
直流電壓可調范圍 |
-10%,+12% |
±20% |
-16%,+10% |
-12%,+11% |
-10%,+20% |
-16%,+10% |
-4%,+18% |
-15%,+17% |
|||
啟動、上升、保持時間 |
200ms,50ms,20ms滿載 |
||||||||||
輸入 |
輸入電壓范圍 |
90~132 VAC/180~264VAC47~63 Hz;由開關選擇254~370VDC |
|||||||||
交流輸入電流 |
5.5A/115 V 3.5A/ 230 V |
||||||||||
效率 |
74% |
76% |
78% |
79% |
78% |
82% |
82% |
83% |
|||
沖擊電流 |
25A/115V50A/230V |
||||||||||
漏電流 |
<3.5 mA/240VAC |
||||||||||
保護特性 |
過載保護 |
105%~135% |
|||||||||
保護方式: 電流限制,自動恢復 |
|||||||||||
過電壓保護 |
115%~135% |
||||||||||
保護方式:打嗝模式,自動恢復 |
|||||||||||
冷卻方式 |
RTH3≥45℃風機開≤40℃風機關,≥85℃切斷輸出 |
||||||||||
環境 |
工作溫度、濕度 |
-10℃~+50℃;20%~90 %RH |
|||||||||
保存溫度、濕度 |
-20℃~+85℃;10%~95 %RH |
||||||||||
抗震性 |
10~500Hz,2G 10min./1周期,時長60分鐘,各軸 |
||||||||||
安全 |
耐壓性 |
輸入輸出間:1.5KVAC輸入與地:1.5KVAC輸出與地:0.5KVAC |
|||||||||
絕緣電阻 |
輸入輸出間,輸入與地,輸出與地:100M Ohms/500VDC |
||||||||||
符合標準 |
安全標準 |
符合UL1950 |
|||||||||
EMC標準 |
符合EN55022,EN55024,EN61000 |
||||||||||
其它 |
重量 |
1.15Kg |
|||||||||
包裝 |
12pcs/13.8Kg/0.98CUFT |
||||||||||
備注 |
1.所有參數在未特別指明時,都是在230VAC電壓輸入,額定負載和25℃條件下測量所得值。 2.紋波和噪聲電壓是在20MHz帶寬示波器帶12英寸雙絞線末端加0.1μ和47μ電容時測得。 3.容差是電壓設定誤差、電壓調整率和電流調整率之總和。 |